Weekend Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmas50

Huawei H13-624 - HCIP-Storage V5.0

Page: 8 / 15
Total 731 questions

In the Huawei Oceanstor 9000 system, which client types are not included in the NFS sharing support?

A.

Host name

B.

IP address

C.

Network group

D.

AD domain

Huawei's hyper-converged storage has multiple data security assurance mechanisms. The following statement is correct ()

A.

Support a variety of EC (Erasure Code) with different ratios

B.

According to the security level, 2 copies or 3 copies can be flexibly configured

C.

Support storage dual-active and asynchronous replication capabilities, and provide cross-site data redundancy protection

D.

PCle SSD Cache technology ensures that data will not be lost after power failure

The remote replication feature is mainly used in disaster recovery and backup scenarios. Which of the following statements about the remote replication feature is correct:

A.

During the remote replication process, if the replication link fails suddenly, the slave L data will be unavailable.

B.

The remote replication slave LUN can be mapped to the host in advance. When the primary L-end fails, it can save business recovery time.

C.

The peak bandwidth of asynchronous replication is higher than that of synchronous replication.

D.

If the disaster recovery solution requires RPO=0, it is recommended to use synchronous remote replication.

What are the necessary components included in the architecture of the N80OONAS system? (multiple choice)

A.

Disk array

B.

NAS engine

C.

Data sharing network equipment

D.

FC switch

In the 10GB network of Huawei 0ceanstor 9000, the switch CE6850-48S4Q-EI can be used. About the switch description.

The correct one is: (multiple choice)

A.

Support up to 32 10GE SFP+ Ethernet optical ports

B.

Support 4 40GE QSFP+ Ethernet ports

C.

The 10GE interface on the switch is used for the interconnection between downstream storage nodes and also for the connection between storage nodes and upstream services

D.

40G E interface is used for stacking between switches

The parameters to be considered when configuring the backup data retention strategy include the policy retention period, retention cycle, and the number of write streams.

A.

True

B.

False

The VSA is installed on the virtual machine, and the MA is installed on the physical machine. Scenarios where this kind of backup networking is not applicable:

A.

DataStore is based on SAN environment

B.

Need to back up directly to tape

C.

A separate backup network can be used to transmit backup data

D.

Physical MA can be used for other backup tasks, and can also be used for AuxCopy

The built-in scripts of the disaster recovery management software OceanStor BCManagereReplication are for Oracle, SQL Server

The application supports one-click failure recovery. Which of the following steps is not included in one-click failure recovery?

A.

The test application starts successfully

B.

Forcibly switch the replication relationship

C.

Start the disaster recovery application

D.

Mapping LUN

(multiple choice) The value of Huawei OceanStor 9000 InfoTier is reflected in:

A.

It can ensure the system's response speed to hot data access and improve the storage performance of the entire system.

B.

Comprehensively utilize the cost advantages of different storage media to effectively reduce deployment and maintenance costs.

C.

Improve system storage performance and realize intelligent data management.

D.

Realize automatic file migration according to the corresponding relationship between file attributes and different storage devices, reducing the cost and complexity of manual management.

Backup strategy management does not include: single selection

A.

Backup time

B.

Back up the network

C.

Backup content

D.

Backup destination

(single choice) Which load balancing method does the Huawei OceanStor 9000 InfoEqualize feature not support?

A.

CPU usage

B.

User Group

C.

Number of node connections

D.

Node throughput

In Huawei’s local high-availability solution, if the HyperMirror feature is adopted, which feature must also be used to correct the difference?

The structure stores the entire column to create a mirror.

A.

HyperMitror

B.

Smartvirtnalization

C.

HyperClone

D.

HirperReplication

The peak write bandwidth of an application is 10MB/s, the average write bandwidth is 200KB/s, and the average write IO size is 4KB (private

The information overhead is about 11%, and the bandwidth utilization rate is 70%). Use FC networking and set to synchronous remote replication mode (consider private

If there is information overhead), which is the correct requirement for network bandwidth?

A.

Greater than or equal to 128.4Mbps

B.

Equal to 128.4Mbps

C.

Less than 128.4Mbps

D.

Greater than or equal to 64.2Mbps

The cascading replication disaster recovery solution establishes a cascading replication relationship for the storage devices used by the business to achieve intra-city disaster recovery + remote disaster recovery, with little impact on the performance of the production center.

A.

True

B.

False

On the basis of inheriting the high reliability design of OceanStor storage system, HyperMetro has newly designed some solutions

Case-level high-reliability technology maximizes the reliability of the storage active-active solution. HyperMetro’s high-reliability technology is mainly reflected in

Which of the following? (multiple choice)

A.

Cross-site cluster

B.

Cross-site data real-time mirroring

C.

Arbitration to prevent split brain

D.

Cross-site bad block repair