Huawei micro-modules can seal cold aisles and hot aisles ()

A.

True

B.

False

FusionModule500&FusionModule800 remote WEB interface monitoring must be configured with unified network management software (

A.

True

B.

False

PowerCube 500 does not need to connect cables or installation, it is directly installed on the pole, and the installation and debugging can be completed in 10 minutes.

A.

True

B.

False

FusionModule800 3.0 closed channel hot and cold channels are optional ()

A.

True

B.

False

The RS485 expansion card in the ECC500 collector can provide 5 RS485 interfaces, and each interface can provide 12V DC output.

A.

True

B.

False

One card of UPS2000-G monitors the entire parallel system, and the parallel system only needs one communication option card to monitor the entire parallel system

A.

True

B.

False

PDu8000 precision power distribution cabinet supports single input and dual input ( ).

A.

True

B.

False

NetEco management system supports reporting alarm information to third-party management system through SNMP interface.

A.

True

B.

False

The cabinet width of Fusionmodule2000 is 600mm and 800mm ( )

A.

True

B.

False

The UPS5000-S has the function of adjusting the number of battery cells to avoid the failure of a single battery to cause the replacement of the entire group, and to solve the problem of difficult maintenance of traditional UPS batteries.

UPS5000-s supports 30-46 battery adjustable. ()

A.

True

B.

False

Huawei Netcol air-cooled air conditioner -- one indoor unit can correspond to multiple outdoor units ()

A.

True

B.

False

By configuring different outdoor units and components, the ambient temperature of Huawei air-cooled in-row precision air conditioners should be: outdoor -40CN ~ +55C, humidity: <=S95%RH

A.

True

B.

False

Lao Wang has been engaged in real estate for many years. Recently, taking advantage of the new infrastructure trend, he has entered the data center. Lao Wang believes that data centers need to choose economical L1 products just like real

estate buildings. ().

A.

True

B.

False

The main circuit input voltage range of UPS2000-G- (6K-20K) models of each capacity is 80V~ 280V, and the input frequency range is 40Hz-70Hz. The ultra-wide input range can effectively

reduce the number of battery switching, avoid fault-prone areas, reduce Battery charge and discharge times to extend battery life. ()

A.

True

B.

False

FusionModule2000 - The integrated UPS supports a maximum of 6 25KVA power modules.

A.

True

B.

False