Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: ecus65

Huawei H19-371_V1.0 - HCS-Pre-sales-Digital Power V1.0

Page: 6 / 13
Total 653 questions

Which core differentiated features of FusionModule800 can shield opponents?

A.

Integrated design of cold and electric control

B.

ibattery

C.

Rack-mounted inverter air conditioner

D.

Air conditioner dehumidification with light load

In a single cabinet configuration scenario, which of the following scenarios can be configured? (

A.

Fusionlodule2000

B.

FusionModule800

C.

FusionModule5000

D.

Fusionlodule500

What is the cabinet depth of Huawei Micro Module 2000? ( )

A.

1000mm

B.

1100mm

C.

1200mm

D.

1500mm

In PDU8000, what are the optional functions (

A.

Input switch remote tripping function

B.

Temperature Monitoring Feature Function

C.

Branch switch hot swap function

D.

9 earthquake resistance

UPS5000-E has the industry-leading reliability design, then the following is correct about the reliability design of UPS5000-E ().

A.

Strong grid adaptability, voltage input range of 138-485V

B.

The veneer is reinforced with conformal paint

C.

More than 1400 test guarantees

D.

40 degrees without derating

12V battery cell, which of the following voltages are acceptable normal use voltages: ()

A.

13V

B.

14.1V

C.

14.52V

D.

10.02V

A project requires the management system to be connected to two third-party generator sets (same model) 1 ATS (same model), six precision air conditioners (same

model), and five smart meters (same model), then the management system Need to report () a third-party device access fee? ()

A.

3

B.

10

C.

14

D.

None of the above is true

When configuring temperature control products, if the temperature of the project location is -10 "30 °C, which of the following working conditions should be preferred

A.

Wide temperature (-40-55℃)

B.

T1 (-20°-45°C)

C.

T3 (-20-55℃)

D.

Ultra-low temperature (-40”45℃)

What is true about the circuit breaker statement :/

A.

The isolating switch and the circuit breaker play the same role in the system

B.

When selecting circuit breakers, do not consider redundancy

C.

The leakage protection circuit breaker is not recommended to be used in the front end of the UPS system

D.

The circuit breaker mainly plays the dual role of isolation and protection in the

system

FusionModule800UPS has a capacity ( ).

A.

10kVA

B.

15kVA

C.

20kVA

D.

30kVA

The new room-level air-cooled series is based on the indoor return air of 35C and the outdoor temperature of 35C. The cooling section has ( )

A.

45kW

B.

50kW

C.

60kW

D.

90kW

E.

100kW

F.

120kW

The NetCol 8000-C room-level chilled water intelligent temperature control product has parts that can be plugged and maintained online, which can greatly reduce the time for parts replacement.

()

A.

Main control module

B.

Auxiliary source module

C.

Electric heating

D.

Fan

The UPS5000-E power chess block adopts the fan fault-tolerant design. When one of the fans is damaged, what percentage of the load can the power module still carry? ( )

A.

0.25

B.

0.3

C.

0.5

D.

0.6

What are the functions of Al-Robot?.

A.

Intelligent recognition

B.

Temperature cloud map

C.

Accompanying visitors

D.

Remote inspection

E.

Automatic inspection

What certifications do Huawei precision column cabinets have (multiple choice)

A.

Earthquake resistance

B.

CE

C.

UL

D.

Thiel