Huawei H19-371_V1.0 - HCS-Pre-sales-Digital Power V1.0

Page: 8 / 13
Total 653 questions

Which of the following are the main features of the UPS2000-G-(6K-20K) PDU?

A.

Realize the input and output power distribution of two parallel machines

B.

Provide single or parallel system centralized maintenance bypass

C.

Extended output socket: OT: 4*C13; 2*C19

D.

Provide surrounding environment monitoring and alarm

Which core differentiated features of FusionModule800 can shield opponents? ( ).

A.

Rack-mounted inverter air conditioner

B.

Integrated design of cold and electric control.

C.

Light-load dehumidification of air conditioners

D.

ibattery.

UPS5000-E (25- 75kVA) integrated cabinet includes () ? (multiple choice)

A.

Input switch

B.

Output switch

C.

Battery switch

D.

Maintenance Bypass Switch

Which of the following conditions are required to calculate the rated input current of the UPS: ( ) (multiple choice)

A.

UPS rated output apparent power

B.

UPS operating nominal efficiency

C.

Battery Inversion Efficiency

D.

UPS battery charging power

The following functions belong to the Fusionmodule2000 controller (ECC800) ( )

A.

Access Control

B.

Alarm Management

C.

Alarm system linkage

Regarding fluorine pump type energy-saving air-conditioning products, which of the following statements is correct ((multiple choice)

A.

No or less compressors are turned on in autumn, winter and spring, indirect natural cooling and energy-saving operation, but it does not necessarily reduce OPEX. Because maintenance work and maintenance difficulty are simultaneously increasing

B.

The reliability of fluorine pump is relatively hidden, and it is easy to be damaged due to cavitation (gaseous refrigerant exists near the blades)

C.

There are no professional pump suppliers for fluorine pumps, and most of them are provided by pump manufacturers. The technology is immature and lacks professional technical support.

D.

At present, the main users are pilot computer rooms of operators and enterprise computer rooms with energy-saving innovation budgets. They have not been applied on a large scale, and are still pending on-site inspection.

E.

In most areas in China, because the temperature in winter is not low enough, the TCO advantage is not obvious. Generally, it takes 5~8 years to recover the investment, and the economy is poor

Which of the following functions does the PDU8000 precision power distribution cabinet have: (multiple choice)

A.

Power distribution function of data center micro-module (cabinet)

B.

The protection function of the lower line and equipment of the precision power distribution cabinet

C.

Main circuit and sub-circuit metering function of precision power distribution cabinet

D.

Abnormal alarm function of main circuit and sub-circuit of precision power distribution cabinet

E.

The precision power distribution cabinet supports SNMP and MODBUS communication, which can transmit information to the intelligent monitoring

system.

UPS system battery intelligent management can fully extend battery life. Which of the following functions does UPS2000-G-(6K 20K) battery management support? () (multiple choice)

A.

Smart Sleep

B.

Automatic floating charge conversion

C.

Temperature supplement

D.

The number of battery cells is adjustable

Regarding the monitoring software NetEco1000U, the following statements are correct ()

A.

Monitor the working status of the UPS in real time and operate the UPS

B.

Support USB, SNMP, MODUBUS network communication

C.

Email alarm, SMS alarm and other alarm reporting functions

D.

SMS alarm needs to be equipped with SMS cat

E.

Provided for free, download and use the answer from the Huawei Support website

as needed

Compared with the fixed frequency structure, the advantages of using the DC frequency conversion structure for air-cooled temperature control products are ( )

A.

On-demand cooling, part-load more energy efficient

B.

Reduce the number of compressor starts and stops, high reliability

C.

Reduce the starting current, less impact on the grid

D.

Continuous cooling, the temperature fluctuation of the equipment room is small.

FusionModule1000A V2R3 version supports operation and maintenance methods (multiple choices)

A.

Local PAD operation and maintenance

B.

Remote mobile phone APP query,

C.

Remote WEB page query

D.

Remote mobile APP control

E.

Access to Huawei NetECO for centralized control

Which of the following functions or components does the UPS5000-E (50kVA power module) come standard with? ( )

A.

SNMP function

B.

Dry contact communication card

C.

Parallel function

D.

Bus synchronization control function

UPS5000-series modular UPS product features are similar to which of the following product models? ( )

A.

Hipulse-u

B.

80-NET

C.

NXr

D.

APM

UPS5000-E-500K Regarding efficiency, which of the following options is correct? ()

A.

Efficiency 96%

B.

Efficiency 94%

C.

ECO mode 99%

D.

ECO mode 98%

Which of the following models has the widest input voltage range and is more suitable for harsh power grids? (

A.

APC Galaxy7000

B.

UPS5000-A

C.

Emerson NXF

D.

Eaton 9395