You are working on the design of a new, large ER/TR that will contain many racks and data cabinets including a large UPS system. Your recommendation to the architect for room access from inside the building is:

A.

Two 0.9 m (3 ft) solid doors

B.

One 1.5 m (5 ft) metallic roll top door

C.

One 1.2 m (4 ft) solid core, steel sheath door

D.

One 1.83 m (6 ft) solid core dual direction sliding door with removable sides

E.

One double door with a removable center post

Which of the following types of conduit uses set screw couplings and connectors?

A.

RMC

B.

EMT

C.

IMC

D.

Schedule 80 PVC

You are recommending to an architect the location within a telecommunications room for the placement of floor sleeves connecting to the telecommunications room directly below. Where should the sleeves be placed within the room?

A.

On the left side of the room at the base of the wall

B.

On the right side of the room at the base of the wall

C.

Centered along the base of the wall

D.

Near the entrance to the room

E.

Conduit should be extended from the sleeves to 2.4 m (8 ft) AFF

You have been selected to do the telecommunications design on a new, single story building. The architect requires the size and location of the telecommunications rooms so their building design can proceed. From the items listed below (all of which are required for the design), which one is the logical starting point in order to provide the architect with a size and location for the room?

A.

Determine where the entrance facility will be

B.

Determine the number of , their locations, and telecommunications services needed

C.

Determine the power, HVAC, electrical, and security requirements for the room

D.

Determine future growth and other requirements

E.

Determine the types of equipment to be installed in the room

In addition to voice and data services, an equipment room (ER) can be designed to include all of the following EXCEPT:

A.

CATV and CCTV facilities

B.

Life safety facilities

C.

Building electrical service monitoring and controls

D.

Audio and paging equipment

E.

General premise monitoring and security systems

Color codes for cross-connections fields have been used for many years. Which color is used to identify campus backbone?

A.

Brown

B.

Blue

C.

Green

D.

Purple

E.

White

When labeling pathways, which one of the following guidelines should be met?

A.

Labeling should be affixed at the ends of each pathway.

B.

Pathways should not be labeled at regular intervals to avoid labeling removal during cable installation.

C.

Avoid marking conduits from the main equipment room (ER).

D.

Pathways do not need to have unique identifiers as they are only supporting cables.

E.

Only pathways containing fire/life/safety systems and electrical system should be labeled to prevent interference with other applications.

Class ________ administration provides for the telecommunications infrastructure administration needs of a single building, or of a tenant served by a single or multiple. It also includes administration for backbone cabling, systems, and.

A.

1

B.

2

C.

3

D.

4

Assume the following:

- An equipment room (ER) consists of 16 racks arranged in 4 equal rows

- The first 4 racks are numbered R1-1 though R1-4

- The second 4 racks are numbered R2-1 through R2-4

- A new equipment shelf with 12 slots is to be installed in the bottom of the third rack in the second row

- Each slot has 2 ports

What would be the identifier of the two ports on the eighth slot of the new equipment shelf?

A.

R2-3-1-8-1 and R2-3-1-8-2

B.

R3-2-1-8-1 and R3-2-1-8-2

C.

R2-3-1-12-1 and R2-3-1-12-2

D.

R3-2-1-12-1 and R3-2-1-12-2

E.

R2-3-12-8-1 and R2-3-12-8-2

Color codes for cross-connections fields have been used for many years. Which color is used to identify horizontal cable?

A.

Blue

B.

Green

C.

Purple

D.

Orange

E.

Brown