Halloween Sale Special - 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: newyear

Cisco 350-601 - Implementing Cisco Data Center Core Technologies v1.1 (350-601 DCCOR)

Page: 8 / 13
Total 422 questions

What happens when the install all epid bootflash:m9000-pkg2-9.2.2.epid module all fan-module all bar all command is run on the Cisco MDS 9000 Series Director Switch?

A.

The active supervisor updates first

B.

Fan modules power cycle

C.

The switching module starts a rolling update

D.

Each module updates and power cycles

An engineer needs to perform a backup of user roles and locales from Cisco UCS Manager to replicate the setting to a different fabric interconnect. The engineer wants to review the file before importing it to a target fabric intercon- nect. Which backup type must be selected to meet these requirements?

A.

all configuration

B.

system configuration

C.

logical configuration

D.

fullstate

An engineer must perform a nondisruptive software upgrade on a dual supervisor Cisco Nexus 7000 series switch. What is the cause of the upgrade being disruptive?

A.

The show install all impact command is not issued before the upgrade.

B.

The kickstart image is installed by using the

C.

Attempt to simultaneously upgrade more than three cards

D.

Change to the configuration setting of the network connections during the upgrade process

An engineer must perform a POAP deployment of a Cisco Nexus 9000 Series Switch The switch must automatically receive its software Image and configuration file upon power-on. Also only UDP Is permitted between the Nexus 9000 switch and the server that hosts the Cisco NX-OS system images. Which set of actions completes the configuration?

A.

Enable option 43Define HTTP transfer protocol.

B.

Enable option 67Define TFTP transfer protocol

C.

Enable option 35.Define HTTP transfer protocol.

D.

Enable option 46Define TFTP transfer protocol.

An engineer must configure an ERSPAN session on a Cisco Nexus 9000 Series Switch. The mirrored traffic originates from the remote IP address 10.10.10.10 and must be forwarded to a network analyzer connected to Ethernet1/10 on the Nexus switch. Which configuration accomplishes this goal?

A.

monitor session 1 rx

source interface all rx

destination interface ethernet1/10

no shut

B.

monitor session 1 type erspan-destination

erspan-id 1

source ip 10.10.10.10

destination interface ethernet1/10

no shut

C.

monitor session 1 type erspan-source

erspan-id 1

source ip 10.10.10.10

source interface ethernet1/10

no shut

D.

monitor session 1 rx

source ip address 10.10.10.10

destination interface ethernet1/10

no shut

Which technology enables RDMA functionality over Ethernet between multiple broadcast domains?

A.

RoCEv1

B.

iWARP

C.

NVMe-oF

D.

RoCEv2

Refer to the exhibit. An engineer implements a VXLAN pod deployment with the vPC. During an upgrade of switches in POD1. Leaf 102 starts to rejoin the vPC pair. Also, traffic to and from the Web Cluster becomes intermittent for five minutes. Which additional command must be applied on both switches to resolve this issue?

A.

auto-recovery reload-delay 180

B.

delay restore orphan-port 180

C.

delay restore interface-vlan 180

D.

dual-active exclude interface-vlan 180

Refer to the exhibit.

A storage engineer creates a new user that is assigned the MDS-Admin role for a Cisco MDS 9000 Series Switch. The now user must be prevented from configuring FSPF. Which snippet must be used in the configuration for the role to provide the required privileges to the new user?

A

A.

rule 4 deny config feature fspf

B.

rule 2 deny config feature fspf

C.

rule 1 deny config feature fspf

D.

rule 5 deny config feature fspf

Refer to the exhibit.

An engineer must activate the port-security database on a Cisco MDS 9000 Series Switch for VSAN 100, but receives the error shown. Which command completes the

configuration?

A.

port-security vsan 100 database active

B.

port-security activate vsan 100 force

C.

port-security enabled mode vsan 100

D.

port-security config-enable vsan 100

Drag and drop the Cisco Nexus 9000 Series Switch software update processes from the left onto the corresponding characteristics on the right.