Weekend Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmas50

IBM C1000-056 - IBM App Connect Enterprise V11 Solution Development

Page: 1 / 2
Total 62 questions

A solution developer sets the maximum rate for a message flow to 100 messages per second. What is this rate evaluated across?

A.

All instances of all input node types.

B.

Each instance of all input node types.

C.

Each instance of each input node type.

D.

All instances of each input node type.

Which statement is true regarding the RESTAsyncResponse node?

A.

It can be in a different integration node as the RESTAsyncRequest node

B.

It has to be in the same integration server as the RESTAsyncRequest node

C.

It can be in a separate integration server than the RESTAsyncRequest node

D.

It has to be in the same flow as the RESTAsyncRequest node

In Linux, what kind of syslog messages are reported by IBM App Connect?

A.

err, warn, or user

B.

err, warn, or info

C.

err, alarm, or info

D.

err, warn, or user

Which statement is true about shared libraries?

A.

If a shared library (A) references another shared library (B), shared library (B) can create a reference to shared library (A)

B.

Static libraries can reference shared libraries but cannot reference other static libraries

C.

Integration Projects can reference shared libraries

D.

A shared library must be deployed with or before an application that references it

What is the correct order of prerequisite steps to install IBM App Connect Enterprise on IBM Cloud Private?

In a message flow, what are two valid event sources of a monitoring event?

A.

Node events

B.

Terminal events

C.

Mapping events

D.

Failover events

E.

Transaction events

When using a GroupScatter node, which terminal allows logging and debugging of groups?

A.

Catch

B.

Published

C.

Group Created

D.

Out

Which two IBM App Connect Toolkit methods can help troubleshoot message flows?

A.

User Trace

B.

Flow Integration Debugger

C.

Flow Debugger

D.

Java Debugger

E.

Flow Exerciser

What is a difference between using Convert Single Project and Convert Multiple Projects when converting from projects to applications and libraries?

A.

Convert Single Project is for one existing project and Convert Multiple Projects is for one or more existing projects.

B.

Convert Single Project is for converting an existing project and any references into one application while Convert Multiple Projects will convert into multiple desired applications with shared libraries.

C.

Convert Single Project will put all artifacts into one application or library, while Convert Multiple Projects will create a new application or library for each existing project.

D.

Only Convert Single Project can convert existing Message Broker projects into IBM App Connect Enterprise applications and libraries, Convert Multiple Projects requires the projects to meet IBM Integration Bus standards before converting.

An Integration Project can contain which two resource types?

A.

Integration Service

B.

Message Flows

C.

Shared Libraries

D.

RestAPIs

E.

Message Maps