DELL EMC D-PE-OE-01 - Dell PowerEdge Operate v2 Exam
A Dell PowerEdge server has Temperature Alert Configuration set up in iDRAC. A Test Event was executed, and email alerts appeared to be delivered successfully. However, a few days later, the server unexpectedly rebooted. Upon inspection, CPU temperatures had exceeded the configured threshold. What is a possible reason IDRAC failed to alert the administrator about the high temperature?
A PSU is blinking green on a PowerEdge R750 while there no issue reported in the iDRAC. What is the most likely cause?
A PowerEdge R760 powers on with no video output. You decide to perform a Minimum-to-POST test. Which configuration correctly represents a valid Minimum-to-POST?
After adding a GPU to a Dell PowerEdge server:
• The operating system does not detect the GPU.
• Lifecycle Controller (LCC) Diagnostics reports a POST failure.
• IDRAC System Event Log shows a GPU power-related error.
What action should be performed first for practical troubleshooting?
A Dell PowerEdge server is experiencing intermittent hardware alerts, and the operating system is occasionally unresponsive. An administrator needs to diagnose and troubleshoot the hardware issue efficiently. Which three tools can be used to troubleshoot hardware issues on a Dell PowerEdge server?
You are asked to perform a quick health check across multiple NVIDIA GPUs in a cluster without impacting running workloads. Which DCGM diagnostic level should be used?
In order to Improve efficiency of the Data Center, the IT department has been tasked with auditing the health and performance, including any sensor alerts, for all Dell servers from the past quarter. Which two basic actions must be taken on the servers in order to obtain the requested information?
A disk fails in a RAID 5 array on a PowerEdge R760. You replace it, but the rebuild process takes longer than expected. What is a possible cause of this behavior?
On a Dell PowerEdge 16G server, iDRAC is configured to use a shared LOM port. What happens if the Auto-Dedicated NIC option is enabled and a dedicated NIC becomes available?
A technician receives a new server with five drives. They need to configure the drives based on the following requirements received from the administrator:
• Drive 0 as a single disk with no RAID
• Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5
The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.
How should the technician configure the drives?