Summer Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmas50

DELL EMC D-PE-OE-01 - Dell PowerEdge Operate v2 Exam

Page: 1 / 2
Total 50 questions

A Dell PowerEdge server has Temperature Alert Configuration set up in iDRAC. A Test Event was executed, and email alerts appeared to be delivered successfully. However, a few days later, the server unexpectedly rebooted. Upon inspection, CPU temperatures had exceeded the configured threshold. What is a possible reason IDRAC failed to alert the administrator about the high temperature?

A.

iDRAC only sends alerts for Critical events or higher.

B.

Although the Temperature Alert was configured, it was not fully activated.

C.

Test Events verify alert delivery but do not trigger actual hardware alerts.

D.

The reboot may have bypassed iDRAC alert mechanisms.

A PSU is blinking green on a PowerEdge R750 while there no issue reported in the iDRAC. What is the most likely cause?

A.

The firmware of the PSU is being updated

B.

This indicates a PSU mismatch

C.

A valid power source is connected to the PSU

D.

indicates an issue with the PSU

A PowerEdge R760 powers on with no video output. You decide to perform a Minimum-to-POST test. Which configuration correctly represents a valid Minimum-to-POST?

A.

One CPU with all associated DIMM, one PSU, no PCIe card

B.

One CPU, one DIMM in the primary channel, one PSU, no PCIe card

C.

Two CPUs installed with all DIMMs populated, one PCIe card

D.

One CPU with all associated DIMM, one PSU, one PCIe card

After adding a GPU to a Dell PowerEdge server:

• The operating system does not detect the GPU.

• Lifecycle Controller (LCC) Diagnostics reports a POST failure.

• IDRAC System Event Log shows a GPU power-related error.

What action should be performed first for practical troubleshooting?

A.

Reset the iDRAC network configuration.

B.

Modify the BIOS Thermal Profile.

C.

Reinstall the GPU driver.

D.

Reseat the GPU in its PCIe slot.

A Dell PowerEdge server is experiencing intermittent hardware alerts, and the operating system is occasionally unresponsive. An administrator needs to diagnose and troubleshoot the hardware issue efficiently. Which three tools can be used to troubleshoot hardware issues on a Dell PowerEdge server?

A.

Operating system application logs

B.

LiveOptics

C.

OME

D.

iDRAC

E.

Lifecycle Controller diagnostics

You are asked to perform a quick health check across multiple NVIDIA GPUs in a cluster without impacting running workloads. Which DCGM diagnostic level should be used?

A.

Level 1

B.

Level 2

C.

Level 3

D.

Level 4

In order to Improve efficiency of the Data Center, the IT department has been tasked with auditing the health and performance, including any sensor alerts, for all Dell servers from the past quarter. Which two basic actions must be taken on the servers in order to obtain the requested information?

A.

Apply iDRAC Enterprise License

B.

Acquire appropriate Login privilege

C.

Set iDRAC networking to use DHCP

D.

Enable RACADM

A disk fails in a RAID 5 array on a PowerEdge R760. You replace it, but the rebuild process takes longer than expected. What is a possible cause of this behavior?

A.

The OS needs updates

B.

The rebuild process slows down the array

C.

The replacement disk is the wrong size

D.

The RAID cache card is disabled

On a Dell PowerEdge 16G server, iDRAC is configured to use a shared LOM port. What happens if the Auto-Dedicated NIC option is enabled and a dedicated NIC becomes available?

A.

iDRAC uses both the shared LOM and dedicated NIC simultaneously for redundancy

B.

iDRAC automatically switches to the dedicated NIC without requiring a reboot

C.

iDRAC disables network connectivity until manually reconfigured

D.

iDRAC continues using the shared LOM port until the next reboot

A technician receives a new server with five drives. They need to configure the drives based on the following requirements received from the administrator:

• Drive 0 as a single disk with no RAID

• Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5

The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.

How should the technician configure the drives?

A.

Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare

B.

Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare

C.

Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare

D.

Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare