EMC D-PSC-MN-01 - Dell PowerScale Maintenance Exam

Page: 1 / 3
Total 101 questions

What type of privileges are required to perform tenant-specific administration?

A.

Zone role-based access control

B.

System root privileges

C.

System admin privileges

D.

Role-based access control

A platform engineer cables, powers up, and creates a new cluster of F600 nodes. While performing verification checks, no clients can access the cluster and the engineer cannot ping the nodes.

What is the probable issue?

A.

Manual reboot was not done following the cluster join.

B.

Network was connected to the F600 rNDC ports.

C.

Nodes were connected to the management ports.

D.

Internal network was cabled improperly.

What type of NIC is used for the external network on a Dell EMC PowerScale F600 node?

A.

1 GbE

B.

10 GbE

C.

25 GbE

D.

40 GbE

What is a consideration when reimaging a Dell PowerScale node?

A.

Perform on a node mat is not a member of a cluster.

B.

Reimaging does not erase the data and is faster.

C.

Perform on a node that Is a member of a cluster.

D.

Use the rolling reimage update to retain the current OneFS version.

What does a blue handle indicate on Dell EMC PowerScale Gen 6 hardware?

A.

Node should be shut down for maintenance procedures

B.

Hardware does not require ESD procedure

C.

Node can remain online during maintenance procedures

D.

Hardware does not require SolVe Desktop activity

What is a precaution when working with Dell EMC PowerScale equipment?

A.

Nodes can operate above 40 degrees C, but only for limited periods of time.

B.

Connections to the branch circuit need not be properly grounded.

C.

Use side stabilizers if the rack is not securely bolted to the floor.

D.

The total rack load should not exceed 70% of the branch circuit rating.

What type of drive should a customer use to ensure that their data is encrypted?

A.

NVMe

B.

SSD

C.

SED

D.

Hard drive

A customer wants to add SSDs to the drive sleds in a Dell PowerScale H600 node for higher storage performance. What should the platform engineer tell the customer?

A.

Cache expansion requires a Dell Professional Services engagement.

B.

Hybrid node SSDs in identical sled locations can be used for either cache or primary storage.

C.

Only F series nodes can use SSDs for primary storage.

D.

Each sled must have an equal number of SSDs.

A platform engineer has built the rack for a Dell EMC PowerScale cluster. While unpacking the components, the engineer notices that the ShockWatch meter has been activated.

A.

Deactivate the ShockWatch meter

B.

Reset the ShockWatch meter

C.

Contact Dell EMC PowerScale Technical Support

D.

Proceed with unpacking the components

What type of NIC can be used for the external network on a Dell PowerScale F600 node?

A.

1/10 GbE

B.

10/100 GbE

C.

10/25 GbE

D.

25/40 GbE