Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: ecus65

EMC D-XTR-DS-A-24 - Dell XtremIO Design Achievement

Page: 2 / 2
Total 60 questions

What is an accurate statement with regards to restoring data to a production volume at a later time using XVC?

A.

There is no need to unmount a production volume before it can be restored

B.

Customer can restore from a read write repurpose copy

C.

Restore option is presented only from a read only copy

D.

Restore operation takes longer than snap shot creation time

How would a storage administrator navigate to different XtremIO clusters from the WebUl if the administrator has more than one cluster managed by the same XMS?

A.

Click on System Settings icon on the top Menu bar

B.

Click the Administration tab and locate the Cluster Name

C.

Click the Cluster Name on the Status bar at the bottom of the screen

D.

Click the Inventory List button on the Navigation Menu

A customer wants you to design an XtremlO solution for an Oracle RAC application environment. The customer maintains two data centers and requires replication to a third site

for disaster recovery purposes. The solution must be fault tolerant and capable of remaining online during planned and unplanned downtime events due to governmental

regulations.

Which Dell EMC technology should be recommended to the customer to meet these requirements?

A.

MetroPoint

B.

ViPR

C.

RecoverPoint/SE

D.

ProtectPoint

What are the I/O Elevators?

A.

1/O scheduling algorithm which controls how I/O operations are submitted to storage.

B.

The maximum number of consecutive "sequential" I/Os allowed to be submitted to storage.

C.

Setting which controls for how long the ESX host attempts to login to the iSCSI target before failing the login.

D.

The amount of SCSI commands (including I/O requests) that can be handled by a storage device at a given time.

A customer has a workload with the following attributes:

. Generates 500,000 IOPs

. Maximum bandwidth of 14 GB/s

Which XtremlO X2 solution should be recommended to the customer?

A.

4 X-Bricks

B.

3 X-Bricks

C.

1 X-Brick

D.

2 X-Bricks

A storage administrator is configuring SAN switches and zoning to connect a four X-Brick XtremlO array. A VMware ESXi server is hosted on a blade chassis with 16 HBA ports.

In addition, the SAN consists of two separate SAN switches.

What is the recommended XtremlO best practice for zoning?

A.

First Storage Controllers' HBA ports to the first switch

Second Storage Controllers' HBA ports to the second switch

Multipath all host ports to single LUNs per zone

B.

Two HBA connections per host

Single initiator/multiple targets per zone

Maximum of 16 paths for each device

Host connected to each SAN switch

C.

Single Storage Controller HBA port to the first switch

Single Storage Controller HBA port to the second switch

Single initiator/multiple targets per zone

Maximum of 4 paths for each LUN per zone

D.

Two HBA connections per host connected to a single switch

Multiple initiators/multiple targets per zone

Maximum of 4 paths for each LUN per zone

Which slot on a physical XtremIO X2 XMS holds the server's boot disk?

A.

3

B.

0

C.

2

D.

1

When using the XtremIO PoC Toolkit, what is the purpose of the Age phase?

A.

Test the performance of the All-Flash array with non-production static data

B.

Overwrite each LUN multiple times to ensure they contain all unique data

C.

Continuously write to a specific range of logical block addresses to test Flash durability

D.

Scatter writes across the entire array to simulate ordinary use of the system