Spring Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmas50

Pure Storage FlashArray-Implementation-Specialist - Pure Certified FlashArray Implementation Specialist (FAIS) Exam

How many power connections are required for the FlashArray//XL chassis?

A.

2

B.

4

C.

6

D.

8

An Implementation Engineer has installed a data pack and the list command shows the drives in "unadmitted" status. Which command should the Implementation Engineer run to complete the admission?

A.

puredrive

B.

puredrive add

C.

purearray drive admit

Where can the NVRAM on a FlashArray//E be located?

A.

Distributed across DFMDs

B.

Distributed across DFMes

C.

Within the dedicated NVRAMs

D.

Distributed across the controller RAM

During an intra-series upgrade from //XR3 to //XR4, which command should the Implementation Engineer run to verify host connectivity before removing the secondary controller?

A.

purehost list --hostless

B.

iobalance --sampletime 30

C.

host_connectivity --hosts

Which action should an Implementation Engineer take to confirm that all volumes connected to a host are automatically in a protection group?

A.

Add the volumes as members of a protection group.

B.

Add a new volume each time it is attached to the host.

C.

Add a host as a member of a protection group.

Prior to running the puresetup newarray command, which command should an Installation Engineer run on a new install of an //XR4 array?

A.

pureboot list

B.

cobalt_check.py

C.

purehw list

A customer would like to reduce SafeMode settings for retention and eradication with their current policy. How is authorization obtained to make the requested changes?

A.

A Pure1 Admin needs to approve any changes for Pure Support to proceed.

B.

Two SafeMode approvers need to acknowledge via Pure1 step-up authentication before any changes can be made.

C.

The local account on FlashArray needs to permit any local changes.

What is the speed of the Ethernet ports to connect a FlashArray //E to a DFS?

A.

40G

B.

25G

C.

100G

On a FlashArray running Purity 6.9.2+, what is the recommended way to initiate a planned controller failover during a FlashArray//XR5 HWNDU?

A.

purewes controller setattr --verify-array < host-name > ct0 --mode secondary

B.

puredb giveback --safe

C.

purendu procedure start giveback

D.

purehw controller failover

During a FlashArray//XR5 upgrade, when should the Implementation Engineer run start_ndu controller-ndu to set the HWNDU specific tunable?

A.

After Purity has been installed on the new //XR5 controller and before it has been initialized.

B.

After the new //XR5 controller has been initialized and before initiating the controller failover.

C.

After the power supply units have been replaced and before stopping Purity on CT0.

D.

Before installing Purity on the new //XR5 controller.