Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?

A.

During the configuration, the engineer needs to configure the SNMP protocol and USM users in the storage system for receiving and querying system alarms.

B.

To view the display format of Syslog content, the engineer can run the "show notification syslog" command.

C.

To change the display format of Syslog content to CEF, the engineer can run the "change syslog-notification format_type=cef" command.

D.

If certificates and CA certificates are generated on the Syslog server, the engineer does not need to perform any operation in the storage system.

A financial customer has purchased multiple Huawei OceanProtect Backup Storage devices for service data backup protection. Which of the following statements are false about the data reduction principle of OceanProtect Backup Storage? choose all that apply

A.

The backup storage can perform deduplication and compression for LUNs but not for file systems.

B.

In the data reduction process, the system performs backup data preprocessing and then variable-length deduplication.

C.

The backup storage performs feature-based compression for different application data. After compression, the data can be directly written to disks without the need to perform any operations.

D.

In the data reduction process, backup data is divided into blocks of a fixed size based on its content for fixed-length deduplication.

Assume a government customer purchased several Huawei scale-out storage devices for service deployment. An engineer needs to configure file services in standard protocol scenarios. Which of the following actions does not need to be performed by the engineer during the configuration?

A.

Install DPC.

B.

Create a converged storage pool.

C.

Create namespaces.

D.

Enable the file service for nodes.

When delivering a flash storage project, Huawei engineers Introduced the SmartMuIti-Tenant feature of flash storage to the customer. Which of the following statements are true about SmartMulti Tenant?

A.

A super administrator can force itself, other super administrators, lightweight directory access protocol (LDAP) users, or LDAP user groups to change their passwords upon the next login.

B.

After a system is upgraded to support the SmartMulti-Tenant feature, all LUNs, file systems, and ports in the original system are allocated to the internal system vStore "System_vStore."

C.

To query system role information, the customer can run the "show role system" command.

D.

In flash storage, only a super administrator can modify vStore information, and the internal system vStore "System_vStore" cannot be modified.

Huawei OceanStor Pacific series storage systems support the _______ client access mode. This mode allows a single client to connect to multiple storage nodes and supports MPI-I/O access. (Enter an acronym.)

A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on the storage devices. Which of the following statements is false about the engineer's configuration?

A.

If upper-layer services require high data security, the engineer needs to set the storage pool type to "Self-encrypting" when creating a converged storage pool.

B.

Before creating a converged storage pool, the engineer must enable the file service for nodes on DeviceManager.

C.

When creating a namespace, the engineer needs to select a security style and application type.

D.

When the storage network is a Remote Direct Memory Access over Converged Ethernet (RoCE) network, the engineer can run the "systemctl stop lldpad.service" command to disable the lldpad service.

A financial customer purchases several Huawel OceanStor Dorado series storage devices for service deployment. During a maintenance process, an engineer needs to use DeviceManager to collect disk health analysis (DHA) logs. Which of the following is not Included in DHA logs?

A.

I/O statistics

B.

Routine disk health statistics

C.

Device latency statistics

D.

Disk life span information

When delivering a flash storage project, Huawei engineers introduced the trusted and secure boot technology of flash storage hardware to the customer. Which of the following statements are true about this technology?

A.

This technology uses digital signatures to verify firmware integrity and prevent firmware and operating systems from being tampered with.

B.

After a device is powered on, the initial startup module starts, and verification is performed level by level. If the verification is successful, the device starts.

C.

During secure boot, the RSA engine verifies the status of the software signature certificate and then verifies the Grub signature public key.

D.

In the overall startup process, Grub needs to be verified and loaded first. After the loading is complete, the Grub signature public key is verified.

A financial customer has purchased two Huawei flash storage devices and installed them in two equipment rooms of a local data center to deploy HyperMetro services. During quorum server network planning, only 10GE quorum links can be used when a single quorum server is deployed. 25GE and Fibre Channel networks cannot be used.

A.

TRUE

B.

FALSE

A financial customer purchases Huawei OceanStor Pacific 9950 for service deployment. During a routine inspection, an engineer finds that a main storage disk of the device is faulty and uses SmartKit to replace it. Which of the following statements is true about replacing the disk?

A.

When removing the disk, the engineer needs to remove it from its connector, wait at least 60 seconds, and then remove the disk from the chassis.

B.

Before using SmartKit to replace the disk, the engineer needs to complete the pre-processing as prompted. After that, the engineer can continue the subsequent operations.

C.

The duration from removing the main storage disk to installing a normal one on the node cannot exceed 10 minutes. Otherwise, heat dissipation of the storage device will be affected.

D.

The interval between removing the faulty disk and inserting a normal one is at least 10 seconds. Otherwise, the disk may be damaged.