Month End Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmas50

Nutanix NCS-Core - Nutanix Certified Services Core Infrastructure Professional (NCS-Core 6.8)

Page: 3 / 10
Total 309 questions

A consultant finishes creating a new ESXi cluster. The consultant connects to the nodes via laptop and a personal flat switch. The host/CVM network is on VLAN 23. The customer has the native VLAN on the ToR switches set to 23.

The customer wants to use LACP. Before placing the nodes on the customer network, the consultant tags VLAN 23 for each host and CVM. The consultant connects the nodes to the customer network and finds that they are unreachable.

What is causing this issue?

A.

The customer has LACP fallback enabled on switch ports.

B.

The hosts have not been migrated to a vSphere Distributed Switch.

C.

Under the vSwitch0 settings, the consultant did not select Route based on IP hash.

D.

The host and CVM are incorrectly configured.

During a six-node cluster deployment, one node fails to image successfully and Foundation is unable to automatically configure the cluster. The consultant decides to manually complete cluster formation with the successful nodes, then expand the cluster with the remaining unconfigured node.

Which command should be used to begin the process?

A.

cluster status

B.

cluster create

C.

cluster start

D.

cluster expand

Where can a consultant find Nutanix Enablement Starter Packs (ESPs)?

A.

In the Partner Portal

B.

In the Nutanix .NEXT Community Forum

C.

In the Support Portal

D.

In the Services section of the Nutanix website.

An administrator has a custom backup application that requires a 2TB disk and runs in Windows. Throughput is considerably lower than expected.

The application was installed on a VM with the following configuration:

• Four vCPUs with one core/vCPU

• 4GB of Memory

• One 50GB vDisk for the Windows installation

• One 2TB vDisk for the application

What is the recommended configuration change to improve throughput?

A.

Increase the number of cores per vCPU

B.

Increase the vCPUs assigned to the VM

C.

Span the 2TB disk across four vDisks

D.

Add 4GB of memory to the VM

A consultant is performing a Nutanix Cluster installation on Dell XC Core hardware. The consultant decides to use Foundation Portable for Mac to perform the installation. When the consultant arrives onsite, Foundation Portable is unable to locate the new nodes.

Which log should the consultant check to troubleshoot this issue?

A.

/home/nutanix/foundation/log

B.

~/data/logs/foundation.out

C.

foundation.app/contents/resouces/log

D.

~/data/logs/foundation

After imaging the nodes and creating the cluster successfully, the consultant connects the cluster to the customer network. When logging into Prism, the events dashboard is full of errors.

What is causing the issue?

A.

The cluster was not stopped prior to connecting to the customer network.

B.

The Cluster Virtual IP Address (VIP) was not set up during the process.

C.

Foundation did not create the cluster successfully.

D.

The consultant did not run Nutanix Cluster Check (NCC)

What reference materials should be provided to the customer during the Knowledge Transfer?

A.

Questionnaire, technical slides and checklist, links to documentation and resources

B.

As-Built Guide, technical slides and checklist, Network Diagram

C.

As-Built Guide, Project Plan, links to documentation and resources

D.

As-Built Guide, technical slides and checklist, links to documentation and resources

A consultant successfully installs the Foundation VM on a laptop and needs to ensure the VM can communicate externally.

Which two configuration changes should the consultant make next? (Choose two.)

A.

Ensure the vNIC is set to bridged adapter.

B.

Configure the static IP address through the desktop virtualization software.

C.

Open terminal and configure via ifconfig command.

D.

Run the set_foundation_ip_address application on the VM desktop.

Refer to Exhibit:

A consultant is conducting cluster deployment using Foundation VM on a laptop.

What troubleshooting step is required?

A.

Disable local machine firewall to ensure its not blocking traffic.

B.

Verify Foundation VM is configured with at least 4GB of memory.

C.

Confirm that TCP port 5123 is open.

D.

Ensure that adaptive endpoint security agents are enabled.

A customer has NearSync configured. When the administrator tries to restore a snapshot from 3 minutes ago, it is not available. The snapshots are happening at 15-minute intervals instead of at the 5-minute configured interval. When the protection domain was initially set up, the snapshots were happening at the expected 5-minute interval.

What should the customer do to enable the snapshots to happen at the expected interval?

A.

Utilize Metro Availability to meet this requirement

B.

Change the protection domain to use Async DR

C.

Fix a connectivity issue because the protection domain reverted to Async

D.

Configure the protection domain to take snapshots on 15-minute intervals