A consultant is completing final network failover testing on a recently deployed AHV cluster.

The cluster consists of the following:

•Three nodes

•Two uplinks connected to two switches

•Supported SFPs

The consultant removed one SFP+ out of each node. Two of the nodes (Hostl I Host2) failed over to the backup NIC correctly without any interruption but have lost communication with the third node (Host 3) hypervisor/CVM. Inserting the original SFP+ back into the problematic node allowed the network to be connected and the two healthy nodes could communicate successfully again.

manage_ovs showjnterfaces output

manage_ovs showjinterfaces output:

name mode link speed

cthO 10000 True 10000

ethl 10000 False None

eth2 10000 True 10000

eth3 10000 False None

manage_ovs show.uplinks output:

Bridge: brO

Bond: brO-up

bond_mode: active-backup

interfaces: ethl ethO

lacp: off

lacp-fa I 1 back: false

lacp_speed: slow

What should the consultant validate first?

A.

Validate NIC card on node is seated properly.

B.

Validate that the correct interfaces are included in the bridge.

C.

Validate the customer has configured all their switch ports identically.

D.

Validate the SFP+ is fully plugged into the node and switch.

A customer already has a Prism Central (PC) instance deployed in their environment and expects the consultant to unregister the old cluster before registering the new cluster

What steps should the consultant take to safely and successfully unregister the customer's former cluster from PC?

A.

Login to any CVM using SSH and use the multicluster command found within NCLi, followed by the unregistration_cleanup.py script on PE and PC.

B.

Login to the PC Web UI, locate the PE cluster and click Unregister from the Actions dropdown menu.

C.

Login to any PCVM using SSH and run the PE_unreglster.py script located in the Nutanix scripts directory, followed by the unregistratlon_cleanup.py script

D.

Login to the PC Web Ul, navigate to Cluster Registrations found under settings in the Admin Center, check the box next to the desired PE. and click Remove

During a technical call with a customer, it is identified that this installation will be software only on Dell servers. The out-of-band management interfaces will not be given IP addresses until the consultant is onsite.

Which Foundation method should be used for this type of installation?

A.

Bare metal using iDRAC MAC addresses.

B.

Bare metal using LAN MAC addresses.

C.

Bare metal using block serial numbers.

D.

Bare metal using node serial numbers.

An administrator has two clusters: Site A and Site B.

Async DR is configured between the clusters as follows:

• Site A is the Primary Site

• Site B is the Secondary inactive Site, no VMs running

• Site A is fully in Production

• Site B used as Backup/Disaster Recovery

The customer wants to perform a planned failover between the sites.

How should the administrator accomplish this?

A.

Click Activate on the Secondary site within the Data Protection Dashboard

B.

Click Activate on the Secondary site and run deactive NCLI command on Primary site

C.

Choose Migrate on the Secondary site within the Data Protection Dashboard

D.

Choose Migrate on the Primary site within the Data Protection Dashboard

An administrator needs to relocate an AHV cluster to a new datacenter during a maintenance window. The cluster will use the same IPs in the new datacenter.

Which two steps should be taken to prepare for this task? (Choose two.)

A.

Stop all Nutanix Files clusters

B.

Relocate the linked LDAP servers

C.

Shut down all user VMs in the cluster

D.

Reconfigure IPMI for the new datacenter

Where in the Support Portal is the Best Practices guide for vSphere Networking located?

A.

Product Notices

B.

Solutions Documentation

C.

Software Documentation

D.

Knowledge Base

An administrator recently added in 3 nodes to an existing 5 node cluster. While 1 node came with its own block, the other 2 nodes where added to an existing share. After adding the nodes, the administrator sees that the hardware tab displays the correct number of nodes, but incorrect position in the diagram tab.

What should the administrator do to resolve the issue?

A.

Check the factory_config.json for all 3 nodes

B.

SSH into CVM and perform genesis restart on each CVM

C.

SSH into the CVMs and run genesis acropolis stop; cluster start

D.

Check the factory_config. json for the two single nodes.

In which part of the Knowledge Transfer can the customer learn how to create, escalate, comment, and close cases?

A.

Operations Guide

B.

Demonstration of the Support Portal

C.

Demonstration of features

D.

Handover Slides and Checklist

A new Nutanix cluster is ready for production on a remote site with no IT staff. Changes to the infrastructure will cost money and probably cause a cluster stop. The administrator needs to perform a health check on the environment that should include:

• Network connectivity checks

• Network performance status

• Storage performance status

Which tool should be used to perform this test?

A.

X-Ray

B.

clurator_cli

C.

NCC

D.

diagnostic, py

A customer has HE servers with DiscoverOS and wants to install a Nutanix cluster.

Which method should a consultant use to meet the requirements?

A.

Manually create the cluster.

B.

Create the cluster using CVM Foundation.

C.

Image the bare metal nodes.

D.

Create the cluster using Crash cart.