Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: ecus65

Nutanix NCS-Core - Nutanix Certified Services Core Infrastructure Professional (NCS-Core 6.8)

Page: 1 / 10
Total 309 questions

An administrator is monitoring the Nutanix v5.15-based AOS cluster performance logs and notices that a SQL server VM is greatly exceeding its intended maximum IOPS. The administrator has confirmed that a QoS policy was previously created for the group of VMs this server is a member of.

What are two reasons that this VM would exceed its maximum configured IOPS from the QoS Policy? (Choose two.)

A.

The VM is missing the required snapshot needed to implement the QoS Policy.

B.

The VM was not created as an AFS virtual machine.

C.

The SQL Server VM has volume groups attached.

D.

It was cloned from another SQL Server VM that was a member of the QoS Policy.

After uploading a hypervisor ISO during the Foundation process, a consultant sees a message that the MD5 sum for the hypervisor is not found in the Whitelist file.

Which step should the consultant take next to resolve this issue?

A.

Download the hypervisor ISO again from the vendor website.

B.

Restart the Foundation process and upload the hypervisor again.

C.

Download the latest hypervisor ISO whitelist file from Nutanix portal.

D.

Check the hypervisor version in the Nutanix Compatibility Matrix.

A CEO asks the IT administrator to provide a list of required resources to protect current workloads and the two new SQL servers from a disaster. The Nutanix environment is managed by Prism Central.

Which option explains how to meet the CEO's request?

A.

In Capacity Runway, select Optimize Resources and select all VMs that must be protected.

B.

Create a new project and assign the VMs to it to get compute and storage requirements.

C.

Create a new scenario based on a new cluster based on a VM Profile and select Recommend.

D.

Create a new Recovery policy by selecting the VM that needs to be protected and get hardware requirements.

After a recent installation using a flat switch, a consultant notices issues migrating the Nutanix nodes to the customer’s network. The customer states that they are using VLANs on the production switch but not on the dedicated switch for IPMI. The customer does not require a manual configuration of the host and CVM.

What network changes need to be made to correct the issues?

A.

Us untagged VLANs for the CVM and host and trunk mode for IPMI.

B.

Use Native VLANs for the CVM and host and access mode for IPMI.

C.

Use tagged VLANs for the CVM and host and access mode for IPMI.

D.

Use Native VLANs for the CVM and host and trunk mode for IPMI.

An administrator is concerned that Prism will be inaccessible if Active Directory is unable to process logins. Which method should the administrator use to access the cluster in the event of this type of outage?

A.

Manage the cluster by using the "nutanix" user on the Prism leader CVM

B.

Create and use an emergency local account on the cluster

C.

Deploy an Active Directory server locally on the cluster

D.

Manage the cluster remotely by downloading ncli to a remote workstation

A customer wants to validate the Microsoft SQL workload performance for a CRM application before migration to the new Nutanix cluster.

Which activity must the consultant add as part of the test plan to fulfill this requirement?

A.

X-Ray with OLAP Workload.

B.

Run perfmon on guest VM.

C.

X-Ray with OLTP Workload.

D.

Run perfmon on all CVMs.

A customer has a four-node cluster and is using Volume Groups to provide storage services to a SQL cluster.

In the event of a CVM failure in the cluster, what is the expected IO path of the volume group’s iSCSI targets?

A.

vDisk directed at failure CVM are redirected to Data Services IP until CVM is reconnected

B.

vDisk directed to CVM that failed to disconnect and will not reconnect without manual intervention

C.

vDisk directed to failed CVM are redirected to another CVM and automatically reconnect

D.

vDisk directed at failed CVM will disconnect and reconnect when the failed CVM comes back online

During the knowledge transfer session, a consultant conducts a storage management demo. In the Creating a Storage Container workflow, the customer notices the Advertised Capacity parameter and asks for an explanation.

How should the consultant respond?

A.

It is a capacity computed by dividing physical storage usage of a container by the replication factor (RF).

B.

It assists in reserving space for a storage container to ensure a maximum storage capacity is available.

C.

It enables the ability to cap usage of storage containers to be smaller than the limit of a storage pool capacity.

D.

It assists in reserving space for a storage container to ensure a minimum storage capacity is available.

An administrator needs to deploy an application with a large amount of data connected via Nutanix Volumes.

Which two actions should the administrator take when designing the Volume Group? (Choose two.)

A.

Use multiple subnets for iSCSI traffic

B.

Enable RSS (Receive Side Scaling)

C.

Enable thick provisioning on the Volume Group(s)

D.

Distribute workload across multiple virtual disks

A consultant is preparing to add new nodes into an existing cluster. The current cluster AOS version is 5.8. The new expansion node is currently running AOS 5.9 code. The cluster must continue to run at its current AOS version.

Which method can be used to successfully add the node?

A.

Upgrade the cluster to 5.9 and add the node through Prism Element.

B.

Use Prism Element to Expand the cluster and select the re-image option.

C.

Use the CLI and enter cluster add-node node-serial=”node_serial”.

D.

Use Prism Element, which will downgrade the node by default during the node add process.