Weekend Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmas50

EMC DES-4122 - Specialist - Implementation Engineer PowerEdge Version 2.0

Page: 1 / 2
Total 60 questions

Which type of access is known as Firmware RACADM on a Dell EMC PowerEdge server?

A.

Accessing RACADM running the Dell Toolkit

B.

Accessing RACADM with OpenManage software

C.

Logging into iDRAC using SSH or Telnet

D.

Logging into iDRAC through Boot Manager

An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment

The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb

What additional component(s) is needed for this configuration?

A.

Hot-plug power supply, 750 W - qty 1

B.

Hot-plug power supply, 1100W - qty 1

C.

Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2

D.

C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2

After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.

Which setting should be changed?

A.

Rebuild Rate in the BIOS settings

B.

System Profile to Performance in the BIOS settings

C.

System Profile to Performance in the iDRAC GUI

D.

Rebuild Rate in the iDRAC GUI

What can be done using in-band management?

A.

Agentless discovery

B.

Firmware and driver updates

C.

Network bandwidth optimization

D.

Remote access

A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?

A.

64 GB

B.

128 GB

C.

256 GB

D.

512 GB

What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?

A.

Network share

B.

vFlash SD card

C.

USB Flash drive

D.

IDSDM SD card

What is the Open Compute Project (OCP) card used for in a Dell EMC PowerEdge server?

A.

Flexibility to choose interconnects

B.

Fixed networking card

C.

Consume a PCIe slot

D.

Provide a hot-swap component

What is the correct order of steps taken during the BIOS/UEFI Recovery process?

A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned

How should the technician obtain access to the remaining 2 TB (approximately) of storage?

A.

Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server

B.

Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB

C.

Upgrade to a newer version of the operating system

D.

Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again

A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

A.

The Virtual Console is disabled

B.

Operating system not installed on remote server

C.

The server has been powered down

D.

There are more than the maximum number of active sessions